{"id":17504,"date":"2026-08-20T00:49:44","date_gmt":"2026-08-20T00:49:44","guid":{"rendered":"https:\/\/pharmamachinecn.com\/?p=17504"},"modified":"2026-08-20T01:30:45","modified_gmt":"2026-08-20T01:30:45","slug":"dissolution-test-for-tablets-and-capsules-complete-guide-2","status":"publish","type":"post","link":"https:\/\/pharmamachinecn.com\/de\/dissolution-test-for-tablets-and-capsules-complete-guide-2\/","title":{"rendered":"Aufl\u00f6sungspr\u00fcfung f\u00fcr Tabletten und Kapseln: Ein umfassender Leitfaden"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"17504\" class=\"elementor elementor-17504\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-656075b4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"656075b4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78348194\" data-id=\"78348194\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2b902b66 product-data-tab elementor-widget elementor-widget-text-editor\" data-id=\"2b902b66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nicht alle Tabletten und Kapseln wirken nach der Einnahme auf die gleiche Weise. Bei einigen wird der Wirkstoff schnell freigesetzt, w\u00e4hrend andere so konzipiert sind, dass sie ihn langsam und \u00fcber einen l\u00e4ngeren Zeitraum hinweg freisetzen. Entscheidend ist, wie effektiv der Wirkstoff im K\u00f6rper verf\u00fcgbar wird.<\/p><figure id=\"attachment_21446\" aria-describedby=\"caption-attachment-21446\" style=\"width: 1605px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-21446\" src=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules.png\" alt=\"Dissolution Test for Tablets and Capsules\" width=\"1605\" height=\"662\" title=\"\" srcset=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules.png 1605w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-300x124.png 300w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-1024x422.png 1024w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-768x317.png 768w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-1536x634.png 1536w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-18x7.png 18w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-500x206.png 500w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-1000x412.png 1000w\" sizes=\"(max-width: 1605px) 100vw, 1605px\" \/><figcaption id=\"caption-attachment-21446\" class=\"wp-caption-text\">Dissolution Test for Tablets and Capsules<\/figcaption><\/figure><p>Genau das soll mit dem Aufl\u00f6sungsversuch f\u00fcr Tabletten und Kapseln gemessen werden. Dieser Versuch spielt in der pharmazeutischen Herstellung eine entscheidende Rolle.<\/p><p>Im Folgenden erl\u00e4utern wir, was der Aufl\u00f6sungs-Test f\u00fcr Tabletten ist, wie er funktioniert und warum er f\u00fcr die Einhaltung gesetzlicher Vorschriften wichtig ist. Dieser Leitfaden beleuchtet au\u00dferdem h\u00e4ufige Herausforderungen bei der Pr\u00fcfung, mit denen Hersteller konfrontiert sind, und zeigt auf, wie diese bew\u00e4ltigt werden k\u00f6nnen.<\/p><h2><strong><b>Was ist ein Aufl\u00f6sungsversuch f\u00fcr Tabletten und Kapseln?<\/b><\/strong><\/h2><figure id=\"attachment_17506\" aria-describedby=\"caption-attachment-17506\" style=\"width: 1020px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-17506\" src=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine.png\" alt=\"Dissolution tester machine\" width=\"1020\" height=\"765\" title=\"\" srcset=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine.png 1020w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-500x375.png 500w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-1000x750.png 1000w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-300x225.png 300w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-768x576.png 768w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-16x12.png 16w\" sizes=\"(max-width: 1020px) 100vw, 1020px\" \/><figcaption id=\"caption-attachment-17506\" class=\"wp-caption-text\"><em><strong>Aufl\u00f6sungspr\u00fcfger\u00e4t.<\/strong><\/em><\/figcaption><\/figure><p>Ein Aufl\u00f6sungsversuch f\u00fcr Tabletten und Kapseln ist definiert als der Vorgang, bei dem die Geschwindigkeit und der Umfang gemessen werden, in denen ein <a href=\"https:\/\/pharmamachinecn.com\/de\/api-in-pharmaceutical-industry-explained\/\"><u>Wirkstoff (API)<\/u><\/a>\u00a0l\u00f6st sich aus einer Tablette oder Kapsel in einer L\u00f6sung auf.<\/p><p>Es handelt sich um ein Laborverfahren, mit dem gemessen wird, wie schnell und in welcher Menge ein Wirkstoff aus seiner <a href=\"https:\/\/pharmamachinecn.com\/de\/what-is-the-dosage-form-definition-in-pharmacy\/\"><u>Darreichungsform<\/u><\/a>\u00a0in ein fl\u00fcssiges Medium. Dieser Test wird unter kontrollierten Bedingungen durchgef\u00fchrt, die die Bedingungen im menschlichen Verdauungstrakt nachbilden.<\/p><p>Sie ist ein wesentlicher Bestandteil der pharmazeutischen Qualit\u00e4tskontrolle und wird von Aufsichtsbeh\u00f6rden wie der US-amerikanischen Food and Drug Administration (FDA) sowie von Arzneib\u00fcchern wie dem <a href=\"https:\/\/www.usp.org\/\" target=\"_blank\" rel=\"noopener\"><u>United States Pharmacopeia<\/u><\/a>.<\/p><h2><strong><b>So funktioniert der Aufl\u00f6setest f\u00fcr Tabletten und Kapseln<\/b><\/strong><\/h2><p><iframe title=\"Capsule and Tablet formulation Dissolution\" src=\"https:\/\/www.youtube.com\/embed\/xU_A8UCQe6g\" width=\"600\" height=\"421\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><span data-mce-type=\"bookmark\" style=\"display: inline-block; width: 0px; overflow: hidden; line-height: 0;\" class=\"mce_SELRES_start\"><\/span><\/iframe><br \/>Hier finden Sie eine Schritt-f\u00fcr-Schritt-Anleitung zur Durchf\u00fchrung des Aufl\u00f6sungsversuchs f\u00fcr Tabletten und Kapseln.<\/p><h3><strong><b>Schritt 1: Das Aufl\u00f6sungsmedium vorbereiten<\/b><\/strong><\/h3><p>Der Prozess beginnt mit der Zubereitung des richtigen Aufl\u00f6sungsmediums. Diese Fl\u00fcssigkeit wird je nach Wirkstoff ausgew\u00e4hlt und ist so konzipiert, dass sie K\u00f6rperfl\u00fcssigkeiten nachahmt. Dabei kann es sich um gereinigtes Wasser, eine Pufferl\u00f6sung oder eine simulierte Magensaftl\u00f6sung handeln.<\/p><p>Das Medium muss genau gemessen und auf den erforderlichen pH-Wert eingestellt werden. In manchen F\u00e4llen ist es au\u00dferdem <a href=\"https:\/\/www.pharmaguideline.com\/2013\/10\/importance-and-method-of-degassing-in-water-system.html\" target=\"_blank\" rel=\"noopener\"><u>entgast<\/u><\/a>\u00a0um Luftblasen zu entfernen, die den Test beeintr\u00e4chtigen k\u00f6nnten. Wird das Medium nicht korrekt vorbereitet, ist der gesamte Test unzuverl\u00e4ssig.<\/p><h3><strong><b>Schritt 2: Temperatur einstellen und stabilisieren<\/b><\/strong><\/h3><p>Sobald das Medium in die Gef\u00e4\u00dfe eingef\u00fcllt ist, wird das System auf <strong>37 \u00b0C (\u00b10,5 \u00b0C).<\/strong> Diese Temperatur entspricht der K\u00f6rpertemperatur des Menschen und muss w\u00e4hrend des gesamten Tests konstant bleiben.<\/p><p>Dem System sollte vor dem Start gen\u00fcgend Zeit gegeben werden, um diese Temperatur zu erreichen und sich darauf einzupendeln. Wird der Test zu fr\u00fch, d.\u202fh. vor Erreichen der Stabilisierung, durchgef\u00fchrt, kann dies zu uneinheitlichen Ergebnissen bei der Wirkstofffreisetzung f\u00fchren.<\/p><h3><strong><b>Schritt 3: Konfigurieren Sie das Ger\u00e4t und die Rotation<\/b><\/strong><\/h3><p>Im n\u00e4chsten Schritt m\u00fcssen Sie die Aufl\u00f6sungsvorrichtung einrichten, in der Regel ein R\u00fchr- oder Korbsystem. Anschlie\u00dfend k\u00f6nnen Sie die Drehzahl entsprechend der Pr\u00fcfmethode einstellen.<\/p><p>Die vom Ger\u00e4t erzeugte Bewegung sorgt daf\u00fcr, dass das Medium auf kontrollierte Weise um die Tablette oder Kapsel herumflie\u00dft. Dadurch wird die nat\u00fcrliche Fl\u00fcssigkeitsbewegung im K\u00f6rper simuliert. Jegliche Unwucht, Vibration oder falsche Geschwindigkeit kann die Aufl\u00f6sung des Wirkstoffs beeintr\u00e4chtigen.<\/p><h3><strong><b>Schritt 4: Legen Sie die Tablette oder Kapsel ein<\/b><\/strong><\/h3><p>Der <a href=\"https:\/\/pharmamachinecn.com\/de\/capsule-vs-tablets\/\"><u>Tablette oder Kapsel<\/u><\/a>\u00a0wird dann in das Gef\u00e4\u00df gegeben. Dies muss vorsichtig geschehen, um ein Zerbrechen oder eine Ver\u00e4nderung der Darreichungsform zu vermeiden.<\/p><p>Sobald die Darreichungsform eingebracht wird, startet der Timer. Ab diesem Zeitpunkt beginnt sich das Medikament aufzul\u00f6sen, und der Test gilt als aktiv.<\/p><h3><strong><b>Schritt 5: Kontrollierte Testbedingungen aufrechterhalten<\/b><\/strong><\/h3><p>W\u00e4hrend des Tests m\u00fcssen alle Bedingungen stabil bleiben. Die Temperatur, die Drehzahl und die Umgebungsbedingungen sollten sich nicht \u00e4ndern. Zum Beispiel:<\/p><ul><li><strong>Die Temperatur muss bei 37 \u00b0C bleiben.<\/strong><\/li><li><strong>Die Drehzahl muss konstant bleiben.<\/strong><\/li><li><strong>\u00c4u\u00dfere St\u00f6rungen sollten vermieden werden.<\/strong><\/li><\/ul><h3><strong><b>Schritt 6: Proben in bestimmten Zeitabst\u00e4nden entnehmen<\/b><\/strong><\/h3><p>Zu festgelegten Zeitpunkten werden Proben aus dem Gef\u00e4\u00df entnommen. Dies geschieht sorgf\u00e4ltig, damit das System nicht gest\u00f6rt wird. Jede Probe gibt Aufschluss dar\u00fcber, wie viel von dem Wirkstoff sich genau zu diesem Zeitpunkt aufgel\u00f6st hat.<\/p><p>Die Entnahmestelle, der Zeitpunkt und die Handhabung m\u00fcssen w\u00e4hrend des gesamten Tests einheitlich bleiben. Jede Abweichung kann zu fehlerhaften Daten f\u00fchren.<\/p><h3><strong><b>Schritt 7: Analyse der Proben<\/b><\/strong><\/h3><p>Die entnommenen Proben werden anschlie\u00dfend mit Laborger\u00e4ten wie UV-Spektralphotometern oder HPLC-Systemen analysiert. In diesem Schritt wird die Konzentration des Wirkstoffs in jeder Probe bestimmt.<\/p><p>Die Ergebnisse werden anschlie\u00dfend in einen Prozentsatz des gel\u00f6sten Wirkstoffs umgerechnet, der als Grundlage f\u00fcr die Auswertung dient.<\/p><h3><strong><b>Schritt 8: Ergebnisse generieren und auswerten<\/b><\/strong><\/h3><p>In diesem Schritt werden die Daten grafisch dargestellt, um ein Aufl\u00f6sungsprofil zu erstellen. Dieses zeigt, wie sich die Freisetzung des Wirkstoffs im Laufe der Zeit entwickelt.<\/p><p>Abschlie\u00dfend werden die Ergebnisse mit vordefinierten Akzeptanzkriterien verglichen. Erf\u00fcllt das Produkt diese Kriterien, hat es den Test bestanden. Ist dies jedoch nicht der Fall, ist der Test fehlgeschlagen, und das Produkt kann ohne weitere Untersuchungen nicht freigegeben werden.<\/p><h2><strong><b>Arten von Aufl\u00f6sungsger\u00e4ten (USP-Methoden)<\/b><\/strong><\/h2><p>Die Aufl\u00f6sungspr\u00fcfung von Tabletten und Kapseln wird unter Verwendung standardisierter Ger\u00e4te durchgef\u00fchrt. Diese Verfahren gew\u00e4hrleisten, dass die Ergebnisse konsistent, vergleichbar und f\u00fcr beh\u00f6rdliche Zwecke akzeptabel sind.<\/p><p>Dazu geh\u00f6ren:<\/p><h3><strong><b>1. Vorrichtung 1 (Korbverfahren)<\/b><\/strong><\/h3><p>Bei diesem Verfahren wird die Tablette oder Kapsel in einen kleinen Drahtkorb gelegt, der sich im Aufl\u00f6sungsmedium dreht. Der Korb h\u00e4lt die Darreichungsform an Ort und Stelle, w\u00e4hrend die Fl\u00fcssigkeit durch ihn hindurchflie\u00dfen kann.<\/p><p>Durch die Rotation entsteht eine kontrollierte Umgebung, in der sich der Wirkstoff allm\u00e4hlich im Medium aufl\u00f6st. Diese Methode eignet sich besonders f\u00fcr <a href=\"https:\/\/pharmamachinecn.com\/de\/types-of-capsule-dosage-forms\/\"><u>Kapseln<\/u><\/a>\u00a0that may float and dosage forms that need to stay contained during testing.<\/p><h3><strong><b>2. Apparatus 2 (Paddle Method)<\/b><\/strong><\/h3><p>The paddle method is the most widely used approach. In this setup, the tablet or capsule is placed directly at the bottom of the vessel, and a rotating paddle stirs the medium above it.<\/p><p>As the paddle rotates, it creates a flow pattern that helps the drug dissolve evenly into the liquid. This method is commonly used for immediate-release tablets and standard capsule formulations.<\/p><h2><strong><b>Common Problems in Dissolution Testing<\/b><\/strong><\/h2><p>Even when the method is validated, dissolution testing can produce unreliable results if small details are missed. Most issues come from setup errors, poor control of conditions, or equipment that is not properly maintained.<\/p><p>These problems are as follows.<\/p><h3><strong><b>1. Inconsistent Results<\/b><\/strong><\/h3><p>One of the most common problems is variation in results between runs or between vessels in the same test. This usually indicates that the test conditions are not fully controlled.<\/p><p>Inconsistency can come from differences in sample placement, timing of sampling, or slight variations in temperature and rotation. Even minor deviations can change how quickly a drug dissolves.<\/p><p>Another cause is variability in the dosage form itself, especially if manufacturing is not tightly controlled.<\/p><h3><strong><b>2. Equipment Issues<\/b><\/strong><\/h3><p>Dissolution equipment must operate precisely. If it does not, the entire test is affected. Problems mostly arise from misalignment, worn components, or lack of calibration. Common equipment-related issues include:<\/p><ul><li><strong>Incorrect rotation speed due to calibration errors.<\/strong><\/li><li><strong>Misaligned paddles or baskets.<\/strong><\/li><li><strong>Temperature control failure.<\/strong><\/li><li><strong>Vibration or instability in the system.<\/strong><\/li><\/ul><p>These issues can change fluid movement inside the vessel, which directly impacts dissolution behavior.<\/p><h3><strong><b>3. Media Errors<\/b><\/strong><\/h3><p>The dissolution medium plays a critical role in the test. If it is not prepared correctly, the results will not reflect actual drug performance.<\/p><p>Errors can occur if:<\/p><ul><li><strong>The pH is outside the specified range.<\/strong><\/li><li><strong>The composition of the medium is incorrect.<\/strong><\/li><li><strong>Air bubbles are present due to poor degassing.<\/strong><\/li><li><strong>The temperature is not properly maintained.<\/strong><\/li><\/ul><p>Since the medium simulates body conditions, any mistake in its preparation can lead to inaccurate conclusions about the drug\u2019s behavior.<\/p><h2><strong><b>FAQs<\/b><\/strong><\/h2><h3><strong><b>1. How is the dissolution test performed for tablets?<\/b><\/strong><\/h3><p>A tablet is placed into a vessel containing a defined volume of dissolution medium at controlled temperature, usually close to body temperature. The paddle or basket rotates at a specified speed, and samples are withdrawn at set time points. The sample is filtered, diluted if needed, and analyzed by UV, HPLC, or another validated assay.<\/p><h3><strong><b>2. What does Q mean in a tablet dissolution test?<\/b><\/strong><\/h3><p>Q is the specified amount of active ingredient that must dissolve at a particular time point. It is not automatically 100%; it is set based on the product, drug release behavior, regulatory expectations, and validated method. In routine QC, Q helps decide whether a batch meets its dissolution specification.<\/p><h3><strong><b>3. Why do tablets fail dissolution testing?<\/b><\/strong><\/h3><p>Tablets may fail dissolution because of excessive hardness, poor wetting, over-compression, high binder level, coating defects, API particle size changes, or aging during stability. Method problems can also create false failures, including wrong RPM, incorrect pH, trapped air bubbles, poor filtration, or vessel alignment issues. A proper investigation should separate product failure from analytical or equipment error.<\/p><h3><strong><b>4. Why are air bubbles a problem in dissolution testing?<\/b><\/strong><\/h3><p>Air bubbles can attach to the tablet, capsule, basket, paddle, or vessel surface and disturb hydrodynamics. They may reduce contact between the dosage form and medium or change the agitation pattern. This can produce variable, low, or misleading dissolution results.<\/p><h2><strong><b>Build Reliable Production That Supports Accurate Testing<\/b><\/strong><\/h2><p>The dissolution test for tablets and capsules is a direct measure of how well your product will perform in real use. If the process is not controlled, the results cannot be trusted, and that puts both product quality and compliance at risk.<\/p><p>However, that\u2019s not the only thing responsible for compliance. You also need the right machinery to stay GMP-compliant, and Finetech provides you with that.<\/p><p>We offer reliable <a href=\"https:\/\/pharmamachinecn.com\/de\/pharmaceutical-machinery\/\"><u>Anlagen zur Herstellung und Verpackung von Arzneimitteln<\/u><\/a>, including filling machines, tablet presses, and more. If you want better control over product performance, the focus should start at production.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/de\/contact-us\/\"><em><u><i>Kontaktieren Sie noch heute unsere Spezialisten.<\/i><\/u><\/em><\/a><em><i>\u00a0to book an appointment!<\/i><\/em><\/p><h2><strong>Referenzen:<\/strong><\/h2><p><a href=\"https:\/\/pharmamachinecn.com\/de\/what-is-solid-dosage-formulation\/\"><span style=\"text-decoration: underline;\"><em><strong>Was ist eine feste Dosierungsformulierung? Einfache Anleitung f\u00fcr alle<\/strong><\/em><\/span><\/a>.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/de\/explore-the-different-types-of-pills\/\"><span style=\"text-decoration: underline;\"><em><strong>Entdecken Sie die verschiedenen Pillenarten: Der vollst\u00e4ndige Leitfaden<\/strong><\/em><\/span><\/a>.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/de\/types-of-tablet-coating\/\"><span style=\"text-decoration: underline;\"><em><strong>Types of Tablet Coating.<\/strong><\/em><\/span><\/a><\/p><p><a href=\"https:\/\/pharmamachinecn.com\/de\/the-truth-about-gelatin\/\"><span style=\"text-decoration: underline;\"><em><strong>Die Wahrheit \u00fcber Gelatine: Zutaten, Quellen und Verwendung<\/strong><\/em><\/span><\/a>.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/de\/the-essential-guide-to-pharmaceutical-capsules\/\"><span style=\"text-decoration: underline;\"><em><strong>Kapseln verstehen: Der grundlegende Leitfaden zu pharmazeutischen Kapseln<\/strong><\/em><\/span><\/a>.<\/p><h2><b>Copyright-Hinweis:<\/b><\/h2><p>Es ist nicht gestattet, Inhalte dieser Website zu vervielf\u00e4ltigen, zu ver\u00e4ndern, zu ver\u00f6ffentlichen, darzustellen, zu \u00fcbermitteln oder in irgendeiner Weise zu verwerten oder solche Inhalte zum Aufbau von Datenbanken jeglicher Art zu verwenden, es sei denn, es liegt eine ausdr\u00fcckliche schriftliche Genehmigung der Finetech Group vor. F\u00fcr eine Genehmigung zur Nutzung des Inhalts wenden Sie sich bitte an: <a href=\"mailto:info@pharmamachinecn.com\"><span style=\"text-decoration: underline;\">info@pharmamachinecn.com<\/span><\/a><\/p><h2><b>Haftungsausschluss:<\/b><\/h2><p>Die in diesem Artikel enthaltenen Informationen dienen lediglich der allgemeinen Information. Das Unternehmen \u00fcbernimmt keine Garantie f\u00fcr die Richtigkeit, Relevanz, Aktualit\u00e4t oder Vollst\u00e4ndigkeit der Informationen, und das Unternehmen \u00fcbernimmt keine Verantwortung f\u00fcr Fehler oder Auslassungen im Inhalt dieses Artikels.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Not all tablets and capsules work the same way once they are taken. Some release their active ingredient quickly, while [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21446,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[67],"tags":[],"class_list":["post-17504","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pills"],"acf":[],"_links":{"self":[{"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/posts\/17504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/comments?post=17504"}],"version-history":[{"count":5,"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/posts\/17504\/revisions"}],"predecessor-version":[{"id":21450,"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/posts\/17504\/revisions\/21450"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/media\/21446"}],"wp:attachment":[{"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/media?parent=17504"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/categories?post=17504"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmamachinecn.com\/de\/wp-json\/wp\/v2\/tags?post=17504"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}