{"id":17504,"date":"2026-08-20T00:49:44","date_gmt":"2026-08-20T00:49:44","guid":{"rendered":"https:\/\/pharmamachinecn.com\/?p=17504"},"modified":"2026-08-20T01:30:45","modified_gmt":"2026-08-20T01:30:45","slug":"dissolution-test-for-tablets-and-capsules-complete-guide-2","status":"publish","type":"post","link":"https:\/\/pharmamachinecn.com\/fr\/dissolution-test-for-tablets-and-capsules-complete-guide-2\/","title":{"rendered":"Essai de dissolution des comprim\u00e9s et des g\u00e9lules : guide complet"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"17504\" class=\"elementor elementor-17504\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-656075b4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"656075b4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78348194\" data-id=\"78348194\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2b902b66 product-data-tab elementor-widget elementor-widget-text-editor\" data-id=\"2b902b66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les comprim\u00e9s et les g\u00e9lules ne fonctionnent pas tous de la m\u00eame mani\u00e8re une fois ing\u00e9r\u00e9s. Certains lib\u00e8rent leur principe actif rapidement, tandis que d'autres sont con\u00e7us pour le lib\u00e9rer progressivement au fil du temps. Ce qui importe, c'est l'efficacit\u00e9 avec laquelle ce principe actif est assimil\u00e9 par l'organisme.<\/p><figure id=\"attachment_21446\" aria-describedby=\"caption-attachment-21446\" style=\"width: 1605px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-21446\" src=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules.png\" alt=\"Dissolution Test for Tablets and Capsules\" width=\"1605\" height=\"662\" title=\"\" srcset=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules.png 1605w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-300x124.png 300w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-1024x422.png 1024w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-768x317.png 768w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-1536x634.png 1536w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-18x7.png 18w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-500x206.png 500w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/08\/Dissolution-Test-for-Tablets-and-Capsules-1000x412.png 1000w\" sizes=\"(max-width: 1605px) 100vw, 1605px\" \/><figcaption id=\"caption-attachment-21446\" class=\"wp-caption-text\">Dissolution Test for Tablets and Capsules<\/figcaption><\/figure><p>C'est pr\u00e9cis\u00e9ment ce que vise \u00e0 mesurer le test de dissolution des comprim\u00e9s et des g\u00e9lules. Ce test joue un r\u00f4le crucial dans la fabrication pharmaceutique.<\/p><p>Nous allons vous expliquer ci-dessous en quoi consiste le test de dissolution des comprim\u00e9s, comment il fonctionne et pourquoi il est essentiel pour la conformit\u00e9 r\u00e9glementaire. Ce guide met \u00e9galement en \u00e9vidence les difficult\u00e9s courantes auxquelles sont confront\u00e9s les fabricants lors des essais, ainsi que les moyens d'y rem\u00e9dier.<\/p><h2><strong><b>Qu'est-ce qu'un essai de dissolution des comprim\u00e9s et des g\u00e9lules ?<\/b><\/strong><\/h2><figure id=\"attachment_17506\" aria-describedby=\"caption-attachment-17506\" style=\"width: 1020px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-17506\" src=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine.png\" alt=\"Dissolution tester machine\" width=\"1020\" height=\"765\" title=\"\" srcset=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine.png 1020w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-500x375.png 500w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-1000x750.png 1000w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-300x225.png 300w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-768x576.png 768w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2026\/05\/Dissolution-tester-machine-16x12.png 16w\" sizes=\"(max-width: 1020px) 100vw, 1020px\" \/><figcaption id=\"caption-attachment-17506\" class=\"wp-caption-text\"><em><strong>Appareil d'essai de dissolution.<\/strong><\/em><\/figcaption><\/figure><p>Un essai de dissolution des comprim\u00e9s et des g\u00e9lules d\u00e9signe le processus consistant \u00e0 mesurer la vitesse et le degr\u00e9 de dissolution d'un <a href=\"https:\/\/pharmamachinecn.com\/fr\/api-in-pharmaceutical-industry-explained\/\"><u>principe actif pharmaceutique (API)<\/u><\/a>\u00a0se dissout \u00e0 partir d'un comprim\u00e9 ou d'une g\u00e9lule pour former une solution.<\/p><p>Il s'agit d'une technique de laboratoire permettant de mesurer la vitesse et la quantit\u00e9 de lib\u00e9ration d'un m\u00e9dicament \u00e0 partir de son <a href=\"https:\/\/pharmamachinecn.com\/fr\/what-is-the-dosage-form-definition-in-pharmacy\/\"><u>forme posologique<\/u><\/a>\u00a0dans un milieu liquide. Ce test est r\u00e9alis\u00e9 dans des conditions contr\u00f4l\u00e9es qui reproduisent l'environnement digestif humain.<\/p><p>Il s'agit d'un \u00e9l\u00e9ment essentiel du contr\u00f4le qualit\u00e9 pharmaceutique et il est exig\u00e9 par les organismes de r\u00e9glementation tels que la Food and Drug Administration (FDA) am\u00e9ricaine et les pharmacop\u00e9es telles que la <a href=\"https:\/\/www.usp.org\/\" target=\"_blank\" rel=\"noopener\"><u>Pharmacop\u00e9e des \u00c9tats-Unis<\/u><\/a>.<\/p><h2><strong><b>Fonctionnement du test de dissolution des comprim\u00e9s et des g\u00e9lules<\/b><\/strong><\/h2><p><iframe title=\"Capsule and Tablet formulation Dissolution\" src=\"https:\/\/www.youtube.com\/embed\/xU_A8UCQe6g\" width=\"600\" height=\"421\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><span data-mce-type=\"bookmark\" style=\"display: inline-block; width: 0px; overflow: hidden; line-height: 0;\" class=\"mce_SELRES_start\"><\/span><\/iframe><br \/>Voici un guide d\u00e9taill\u00e9 expliquant le fonctionnement du test de dissolution des comprim\u00e9s et des g\u00e9lules.<\/p><h3><strong><b>\u00c9tape 1 : Pr\u00e9paration du milieu de dissolution<\/b><\/strong><\/h3><p>Le processus commence par la pr\u00e9paration du milieu de dissolution appropri\u00e9. Ce liquide est choisi en fonction du m\u00e9dicament et est con\u00e7u pour imiter les fluides corporels. Il peut s'agir d'eau purifi\u00e9e, d'une solution tampon ou d'un simulant de suc gastrique.<\/p><p>Le milieu doit \u00eatre dos\u00e9 avec pr\u00e9cision et ajust\u00e9 au pH requis. Dans certains cas, il est \u00e9galement <a href=\"https:\/\/www.pharmaguideline.com\/2013\/10\/importance-and-method-of-degassing-in-water-system.html\" target=\"_blank\" rel=\"noopener\"><u>d\u00e9gaz\u00e9<\/u><\/a>\u00a0pour \u00e9liminer les bulles d'air susceptibles d'alt\u00e9rer les r\u00e9sultats du test. Si le milieu n'est pas pr\u00e9par\u00e9 correctement, l'ensemble du test perd toute fiabilit\u00e9.<\/p><h3><strong><b>\u00c9tape 2 : R\u00e9gler et stabiliser la temp\u00e9rature<\/b><\/strong><\/h3><p>Une fois le milieu introduit dans les r\u00e9cipients, le syst\u00e8me est chauff\u00e9 \u00e0 <strong>37 \u00b0C (\u00b1 0,5 \u00b0C).<\/strong> Cette temp\u00e9rature correspond \u00e0 celle du corps humain et doit rester stable tout au long du test.<\/p><p>Il convient de laisser au syst\u00e8me suffisamment de temps pour atteindre cette temp\u00e9rature et se stabiliser \u00e0 ce niveau avant de d\u00e9marrer. Effectuer le test trop t\u00f4t, avant que le syst\u00e8me ne se soit stabilis\u00e9, peut entra\u00eener des r\u00e9sultats incoh\u00e9rents concernant la lib\u00e9ration du m\u00e9dicament.<\/p><h3><strong><b>\u00c9tape 3 : Configuration de l'appareil et de la rotation<\/b><\/strong><\/h3><p>\u00c0 l'\u00e9tape suivante, vous devez mettre en place l'appareil de dissolution, qui consiste g\u00e9n\u00e9ralement en un syst\u00e8me \u00e0 pale ou \u00e0 panier. Vous pouvez ensuite r\u00e9gler la vitesse de rotation conform\u00e9ment \u00e0 la m\u00e9thode d'essai.<\/p><p>Le mouvement g\u00e9n\u00e9r\u00e9 par l'appareil garantit que le milieu s'\u00e9coule autour du comprim\u00e9 ou de la g\u00e9lule de mani\u00e8re contr\u00f4l\u00e9e. Cela reproduit le mouvement naturel des fluides dans l'organisme. Tout d\u00e9s\u00e9quilibre, toute vibration ou toute vitesse inadapt\u00e9e peut alt\u00e9rer la dissolution du m\u00e9dicament.<\/p><h3><strong><b>\u00c9tape 4 : Introduire le comprim\u00e9 ou la g\u00e9lule<\/b><\/strong><\/h3><p>Le <a href=\"https:\/\/pharmamachinecn.com\/fr\/capsule-vs-tablets\/\"><u>comprim\u00e9 ou g\u00e9lule<\/u><\/a>\u00a0est ensuite plac\u00e9e dans le r\u00e9cipient. Cette op\u00e9ration doit \u00eatre effectu\u00e9e avec pr\u00e9caution afin d'\u00e9viter de casser ou d'alt\u00e9rer la forme gal\u00e9nique.<\/p><p>D\u00e8s que la forme gal\u00e9nique est introduite, le chronom\u00e8tre d\u00e9marre. \u00c0 partir de ce moment, le m\u00e9dicament commence \u00e0 se dissoudre et le test est consid\u00e9r\u00e9 comme actif.<\/p><h3><strong><b>\u00c9tape 5 : Maintenir des conditions d'essai contr\u00f4l\u00e9es<\/b><\/strong><\/h3><p>Pendant l'essai, toutes les conditions doivent rester stables. La temp\u00e9rature, la vitesse de rotation et l'environnement ne doivent pas varier. Par exemple :<\/p><ul><li><strong>La temp\u00e9rature doit rester \u00e0 37 \u00b0C.<\/strong><\/li><li><strong>La vitesse de rotation doit rester constante.<\/strong><\/li><li><strong>Il convient d'\u00e9viter toute perturbation ext\u00e9rieure.<\/strong><\/li><\/ul><h3><strong><b>\u00c9tape 6 : Pr\u00e9lever des \u00e9chantillons \u00e0 intervalles r\u00e9guliers<\/b><\/strong><\/h3><p>Des \u00e9chantillons sont pr\u00e9lev\u00e9s dans le r\u00e9cipient \u00e0 des moments pr\u00e9d\u00e9finis. Cette op\u00e9ration est effectu\u00e9e avec pr\u00e9caution afin de ne pas perturber le syst\u00e8me. Chaque \u00e9chantillon refl\u00e8te la quantit\u00e9 de m\u00e9dicament qui s'est dissoute \u00e0 ce moment pr\u00e9cis.<\/p><p>La position de pr\u00e9l\u00e8vement, le moment du pr\u00e9l\u00e8vement et la manipulation doivent rester constants tout au long de l'essai. Toute variation peut entra\u00eener des donn\u00e9es erron\u00e9es.<\/p><h3><strong><b>\u00c9tape 7 : Analyser les \u00e9chantillons<\/b><\/strong><\/h3><p>Les \u00e9chantillons pr\u00e9lev\u00e9s sont ensuite analys\u00e9s \u00e0 l'aide d'appareils de laboratoire tels que des spectrophotom\u00e8tres UV ou des syst\u00e8mes HPLC. Cette \u00e9tape permet de d\u00e9terminer la concentration du m\u00e9dicament dans chaque \u00e9chantillon.<\/p><p>Les r\u00e9sultats sont ensuite convertis en pourcentage de principe actif dissous, ce qui sert de base \u00e0 l'\u00e9valuation.<\/p><h3><strong><b>\u00c9tape 8 : G\u00e9n\u00e9rer et analyser les r\u00e9sultats<\/b><\/strong><\/h3><p>Au cours de cette \u00e9tape, les donn\u00e9es sont repr\u00e9sent\u00e9es graphiquement afin d'\u00e9tablir un profil de dissolution. Celui-ci montre comment le principe actif est lib\u00e9r\u00e9 au fil du temps.<\/p><p>Enfin, les r\u00e9sultats sont compar\u00e9s \u00e0 des crit\u00e8res d'acceptation pr\u00e9d\u00e9finis. Si le produit r\u00e9pond \u00e0 ces crit\u00e8res, il r\u00e9ussit le test. En revanche, s'il ne les remplit pas, il \u00e9choue et ne peut \u00eatre mis sur le march\u00e9 sans une analyse plus approfondie.<\/p><h2><strong><b>Types d'appareils de dissolution (m\u00e9thodes USP)<\/b><\/strong><\/h2><p>L'essai de dissolution des comprim\u00e9s et des g\u00e9lules est r\u00e9alis\u00e9 \u00e0 l'aide d'\u00e9quipements normalis\u00e9s. Ces m\u00e9thodes garantissent que les r\u00e9sultats sont coh\u00e9rents, comparables et acceptables d'un point de vue r\u00e9glementaire.<\/p><p>Cela comprend :<\/p><h3><strong><b>1. Appareil n\u00b0 1 (m\u00e9thode du panier)<\/b><\/strong><\/h3><p>Dans cette m\u00e9thode, le comprim\u00e9 ou la g\u00e9lule est plac\u00e9(e) \u00e0 l'int\u00e9rieur d'un petit panier en treillis m\u00e9tallique qui tourne dans le milieu de dissolution. Le panier maintient la forme gal\u00e9nique en place tout en permettant au liquide de s'\u00e9couler \u00e0 travers celui-ci.<\/p><p>La rotation cr\u00e9e un environnement contr\u00f4l\u00e9 dans lequel le m\u00e9dicament se dissout progressivement dans le milieu. Cette m\u00e9thode est particuli\u00e8rement utile pour <a href=\"https:\/\/pharmamachinecn.com\/fr\/types-of-capsule-dosage-forms\/\"><u>capsules<\/u><\/a>\u00a0that may float and dosage forms that need to stay contained during testing.<\/p><h3><strong><b>2. Apparatus 2 (Paddle Method)<\/b><\/strong><\/h3><p>The paddle method is the most widely used approach. In this setup, the tablet or capsule is placed directly at the bottom of the vessel, and a rotating paddle stirs the medium above it.<\/p><p>As the paddle rotates, it creates a flow pattern that helps the drug dissolve evenly into the liquid. This method is commonly used for immediate-release tablets and standard capsule formulations.<\/p><h2><strong><b>Common Problems in Dissolution Testing<\/b><\/strong><\/h2><p>Even when the method is validated, dissolution testing can produce unreliable results if small details are missed. Most issues come from setup errors, poor control of conditions, or equipment that is not properly maintained.<\/p><p>These problems are as follows.<\/p><h3><strong><b>1. Inconsistent Results<\/b><\/strong><\/h3><p>One of the most common problems is variation in results between runs or between vessels in the same test. This usually indicates that the test conditions are not fully controlled.<\/p><p>Inconsistency can come from differences in sample placement, timing of sampling, or slight variations in temperature and rotation. Even minor deviations can change how quickly a drug dissolves.<\/p><p>Another cause is variability in the dosage form itself, especially if manufacturing is not tightly controlled.<\/p><h3><strong><b>2. Equipment Issues<\/b><\/strong><\/h3><p>Dissolution equipment must operate precisely. If it does not, the entire test is affected. Problems mostly arise from misalignment, worn components, or lack of calibration. Common equipment-related issues include:<\/p><ul><li><strong>Incorrect rotation speed due to calibration errors.<\/strong><\/li><li><strong>Misaligned paddles or baskets.<\/strong><\/li><li><strong>Temperature control failure.<\/strong><\/li><li><strong>Vibration or instability in the system.<\/strong><\/li><\/ul><p>These issues can change fluid movement inside the vessel, which directly impacts dissolution behavior.<\/p><h3><strong><b>3. Media Errors<\/b><\/strong><\/h3><p>The dissolution medium plays a critical role in the test. If it is not prepared correctly, the results will not reflect actual drug performance.<\/p><p>Errors can occur if:<\/p><ul><li><strong>The pH is outside the specified range.<\/strong><\/li><li><strong>The composition of the medium is incorrect.<\/strong><\/li><li><strong>Air bubbles are present due to poor degassing.<\/strong><\/li><li><strong>The temperature is not properly maintained.<\/strong><\/li><\/ul><p>Since the medium simulates body conditions, any mistake in its preparation can lead to inaccurate conclusions about the drug\u2019s behavior.<\/p><h2><strong><b>FAQ<\/b><\/strong><\/h2><h3><strong><b>1. How is the dissolution test performed for tablets?<\/b><\/strong><\/h3><p>A tablet is placed into a vessel containing a defined volume of dissolution medium at controlled temperature, usually close to body temperature. The paddle or basket rotates at a specified speed, and samples are withdrawn at set time points. The sample is filtered, diluted if needed, and analyzed by UV, HPLC, or another validated assay.<\/p><h3><strong><b>2. What does Q mean in a tablet dissolution test?<\/b><\/strong><\/h3><p>Q is the specified amount of active ingredient that must dissolve at a particular time point. It is not automatically 100%; it is set based on the product, drug release behavior, regulatory expectations, and validated method. In routine QC, Q helps decide whether a batch meets its dissolution specification.<\/p><h3><strong><b>3. Why do tablets fail dissolution testing?<\/b><\/strong><\/h3><p>Tablets may fail dissolution because of excessive hardness, poor wetting, over-compression, high binder level, coating defects, API particle size changes, or aging during stability. Method problems can also create false failures, including wrong RPM, incorrect pH, trapped air bubbles, poor filtration, or vessel alignment issues. A proper investigation should separate product failure from analytical or equipment error.<\/p><h3><strong><b>4. Why are air bubbles a problem in dissolution testing?<\/b><\/strong><\/h3><p>Air bubbles can attach to the tablet, capsule, basket, paddle, or vessel surface and disturb hydrodynamics. They may reduce contact between the dosage form and medium or change the agitation pattern. This can produce variable, low, or misleading dissolution results.<\/p><h2><strong><b>Build Reliable Production That Supports Accurate Testing<\/b><\/strong><\/h2><p>The dissolution test for tablets and capsules is a direct measure of how well your product will perform in real use. If the process is not controlled, the results cannot be trusted, and that puts both product quality and compliance at risk.<\/p><p>However, that\u2019s not the only thing responsible for compliance. You also need the right machinery to stay GMP-compliant, and Finetech provides you with that.<\/p><p>We offer reliable <a href=\"https:\/\/pharmamachinecn.com\/fr\/pharmaceutical-machinery\/\"><u>\u00e9quipements de fabrication et de conditionnement pharmaceutiques<\/u><\/a>, including filling machines, tablet presses, and more. If you want better control over product performance, the focus should start at production.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/fr\/contact-us\/\"><em><u><i>Contactez nos sp\u00e9cialistes d\u00e8s aujourd&#039;hui<\/i><\/u><\/em><\/a><em><i>\u00a0to book an appointment!<\/i><\/em><\/p><h2><strong>R\u00e9f\u00e9rences :<\/strong><\/h2><p><a href=\"https:\/\/pharmamachinecn.com\/fr\/what-is-solid-dosage-formulation\/\"><span style=\"text-decoration: underline;\"><em><strong>Qu&#039;est-ce qu&#039;une formulation solide\u00a0? Guide simple pour tous<\/strong><\/em><\/span><\/a>.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/fr\/explore-the-different-types-of-pills\/\"><span style=\"text-decoration: underline;\"><em><strong>Explorez les diff\u00e9rents types de pilules\u00a0: le guide complet<\/strong><\/em><\/span><\/a>.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/fr\/types-of-tablet-coating\/\"><span style=\"text-decoration: underline;\"><em><strong>Types of Tablet Coating.<\/strong><\/em><\/span><\/a><\/p><p><a href=\"https:\/\/pharmamachinecn.com\/fr\/the-truth-about-gelatin\/\"><span style=\"text-decoration: underline;\"><em><strong>La v\u00e9rit\u00e9 sur la g\u00e9latine\u00a0: ingr\u00e9dients, sources et utilisations<\/strong><\/em><\/span><\/a>.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/fr\/the-essential-guide-to-pharmaceutical-capsules\/\"><span style=\"text-decoration: underline;\"><em><strong>Comprendre les capsules\u00a0: Le guide essentiel des capsules pharmaceutiques<\/strong><\/em><\/span><\/a>.<\/p><h2><b>Avis de droit d'auteur :<\/b><\/h2><p>Vous ne pouvez pas reproduire, modifier, publier, afficher, transmettre ou exploiter de quelque mani\u00e8re que ce soit le contenu de ce site web, ni utiliser ce contenu pour constituer une base de donn\u00e9es de quelque nature que ce soit, sans l'autorisation \u00e9crite expresse et pr\u00e9alable de Finetech Group. Pour obtenir l'autorisation d'utiliser le contenu, veuillez contacter : <a href=\"mailto:info@pharmamachinecn.com\"><span style=\"text-decoration: underline;\">info@pharmamachinecn.com<\/span><\/a><\/p><h2><b>Clause de non-responsabilit\u00e9:<\/b><\/h2><p>Les informations contenues dans cet article sont fournies \u00e0 titre d'information g\u00e9n\u00e9rale uniquement. L'entreprise ne garantit pas l'exactitude, la pertinence, l'actualit\u00e9 ou l'exhaustivit\u00e9 des informations, et l'entreprise n'assume aucune responsabilit\u00e9 en cas d'erreur ou d'omission dans le contenu de cet article.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Not all tablets and capsules work the same way once they are taken. Some release their active ingredient quickly, while [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21446,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[67],"tags":[],"class_list":["post-17504","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pills"],"acf":[],"_links":{"self":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts\/17504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/comments?post=17504"}],"version-history":[{"count":5,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts\/17504\/revisions"}],"predecessor-version":[{"id":21450,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts\/17504\/revisions\/21450"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/media\/21446"}],"wp:attachment":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/media?parent=17504"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/categories?post=17504"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/tags?post=17504"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}