{"id":8819,"date":"2025-12-23T00:49:23","date_gmt":"2025-12-23T00:49:23","guid":{"rendered":"https:\/\/pharmamachinecn.com\/?p=8819"},"modified":"2026-05-05T15:53:49","modified_gmt":"2026-05-05T15:53:49","slug":"tablet-coating-defects-and-remedies-you-should-know","status":"publish","type":"post","link":"https:\/\/pharmamachinecn.com\/fr\/tablet-coating-defects-and-remedies-you-should-know\/","title":{"rendered":"D\u00e9fauts d&#039;enrobage des comprim\u00e9s et solutions \u00e0 conna\u00eetre"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"8819\" class=\"elementor elementor-8819\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-656075b4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"656075b4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78348194\" data-id=\"78348194\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2b902b66 product-data-tab elementor-widget elementor-widget-text-editor\" data-id=\"2b902b66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L&#039;enrobage des comprim\u00e9s peut para\u00eetre simple au premier abord, mais dans l&#039;industrie pharmaceutique, c&#039;est souvent l\u00e0 que les probl\u00e8mes surviennent. Fissures, d\u00e9collement, couleurs irr\u00e9guli\u00e8res ou textures rugueuses rendent les comprim\u00e9s peu attrayants.<\/p><figure id=\"attachment_8944\" aria-describedby=\"caption-attachment-8944\" style=\"width: 983px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-8944\" src=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/types-of-tablet-defects.jpg\" alt=\"types de d\u00e9fauts de tablettes\" width=\"983\" height=\"1129\" srcset=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/types-of-tablet-defects.jpg 983w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/types-of-tablet-defects-261x300.jpg 261w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/types-of-tablet-defects-892x1024.jpg 892w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/types-of-tablet-defects-768x882.jpg 768w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/types-of-tablet-defects-10x12.jpg 10w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/types-of-tablet-defects-600x689.jpg 600w\" sizes=\"(max-width: 983px) 100vw, 983px\" \/><figcaption id=\"caption-attachment-8944\" class=\"wp-caption-text\"><strong>Types de d\u00e9fauts des tablettes.<\/strong><\/figcaption><\/figure><p>En effet, les d\u00e9fauts d&#039;enrobage des comprim\u00e9s figurent parmi les probl\u00e8mes de qualit\u00e9 les plus fr\u00e9quemment relev\u00e9s lors des contr\u00f4les. La bonne nouvelle\u00a0? La plupart de ces probl\u00e8mes ont une cause pr\u00e9cise, et une fois identifi\u00e9es, elles permettent de les corriger ou de les pr\u00e9venir.<\/p><p>Dans ce guide, nous allons donc d\u00e9tailler les principaux d\u00e9fauts d&#039;enrobage des comprim\u00e9s et les solutions que vous pouvez appliquer.<\/p><h2><strong>Points cl\u00e9s \u00e0 retenir\u00a0: D\u00e9fauts d\u2019enrobage des comprim\u00e9s et solutions<\/strong><\/h2><ul><li><strong>D\u00e9fauts d&#039;enrobage des comprim\u00e9s<\/strong>Ces d\u00e9fauts, tels que l&#039;adh\u00e9rence, les fissures, les variations de couleur et l&#039;\u00e9rosion, sont dus \u00e0 un contr\u00f4le insuffisant du processus et \u00e0 un s\u00e9chage inad\u00e9quat. Chacun peut \u00eatre corrig\u00e9 en ajustant le d\u00e9bit de pulv\u00e9risation, le flux d&#039;air ou la vitesse de manipulation.<\/li><li><strong>Probl\u00e8mes de compression des tablettes<\/strong>Les probl\u00e8mes tels que le bouchage, l&#039;adh\u00e9rence, l&#039;\u00e9caillage ou les variations de poids r\u00e9sultent principalement de propri\u00e9t\u00e9s granulaires inad\u00e9quates, d&#039;une vitesse trop \u00e9lev\u00e9e ou d&#039;un liant insuffisant. Pour y rem\u00e9dier, on peut opter pour une meilleure granulation et un dosage appropri\u00e9 du liant.<\/li><li><strong>Probl\u00e8mes de traitement avant rev\u00eatement<\/strong>L&#039;humidit\u00e9, la fragilit\u00e9 du noyau ou les irr\u00e9gularit\u00e9s dimensionnelles peuvent entra\u00eener des d\u00e9fauts de rev\u00eatement. Il est possible d&#039;\u00e9liminer ces probl\u00e8mes en contr\u00f4lant l&#039;humidit\u00e9 et en renfor\u00e7ant le noyau.<\/li><\/ul><h2><strong>D\u00e9fauts courants d&#039;enrobage des comprim\u00e9s et solutions<\/strong><\/h2><p>L&#039;enrobage des comprim\u00e9s repose sur un \u00e9quilibre d\u00e9licat entre science et ma\u00eetrise des proc\u00e9d\u00e9s. Ces d\u00e9fauts alt\u00e8rent l&#039;aspect esth\u00e9tique du produit et peuvent m\u00eame, dans certains cas, alt\u00e9rer la stabilit\u00e9 du principe actif. Voici les d\u00e9fauts d&#039;enrobage les plus courants et leurs solutions.<\/p><h3><strong>1. Grattage et collage<\/strong><\/h3><p>Il arrive que l&#039;enrobage ne reste pas sur la pastille et se colle au plateau, \u00e0 la buse de pulv\u00e9risation, voire \u00e0 d&#039;autres pastilles. Ce ph\u00e9nom\u00e8ne, appel\u00e9 d\u00e9collement et collage, laisse des zones rugueuses, des taches, voire des trous l\u00e0 o\u00f9 l&#039;enrobage est absent.<\/p><figure id=\"attachment_8956\" aria-describedby=\"caption-attachment-8956\" style=\"width: 842px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-8956\" src=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/Sticking-and-Picking-Tablet-Defect.png\" alt=\"D\u00e9faut de collage et de d\u00e9collement des comprim\u00e9s\" width=\"842\" height=\"344\" srcset=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/Sticking-and-Picking-Tablet-Defect.png 842w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/Sticking-and-Picking-Tablet-Defect-300x123.png 300w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/Sticking-and-Picking-Tablet-Defect-768x314.png 768w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/Sticking-and-Picking-Tablet-Defect-18x7.png 18w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/12\/Sticking-and-Picking-Tablet-Defect-600x245.png 600w\" sizes=\"(max-width: 842px) 100vw, 842px\" \/><figcaption id=\"caption-attachment-8956\" class=\"wp-caption-text\"><strong>D\u00e9faut de collage et de d\u00e9collement des comprim\u00e9s<\/strong><\/figcaption><\/figure><p>La principale cause est le sur-humidification, due \u00e0 l&#039;application excessive de solution sans s\u00e9chage suffisant. N&#039;oubliez pas que les rev\u00eatements collants ou une forte humidit\u00e9 peuvent aggraver le probl\u00e8me.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>R\u00e9duisez le <a href=\"https:\/\/www.pharmainform.com\/2023\/04\/spray-rate-calculations-for-tablet-coating.html\" target=\"_blank\" rel=\"noopener\"><u>d\u00e9bit de pulv\u00e9risation<\/u><\/a>\u00a0pour \u00e9viter un exc\u00e8s d&#039;humidit\u00e9, et augmenter l\u00e9g\u00e8rement le flux d&#039;air de s\u00e9chage afin que le film de rev\u00eatement durcisse plus rapidement.<\/p><h3><strong>2. Craquage<\/strong><\/h3><p>Les fissures se manifestent par de fines craquelures capillaires qui apparaissent \u00e0 la surface du rev\u00eatement. Elles r\u00e9sultent g\u00e9n\u00e9ralement d&#039;une fragilit\u00e9 excessive du film due \u00e0 une quantit\u00e9 insuffisante de produit. <a href=\"https:\/\/www.sciencedirect.com\/topics\/materials-science\/plasticizer\" target=\"_blank\" rel=\"noopener\"><u>teneur en plastifiant<\/u><\/a>, ou bien la machine s\u00e8che les comprim\u00e9s trop rapidement.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Augmenter la quantit\u00e9 de plastifiant dans la formulation et ralentir la vitesse de s\u00e9chage afin de maintenir la flexibilit\u00e9 du film.<\/p><h3><strong>3. Variation de couleur<\/strong><\/h3><p>Au lieu d&#039;un aspect uniforme, les comprim\u00e9s peuvent pr\u00e9senter des irr\u00e9gularit\u00e9s de couleur ou des zones plus claires et plus fonc\u00e9es. Cela peut leur donner un aspect vieilli ou de mauvaise qualit\u00e9. Ce probl\u00e8me est d\u00fb \u00e0 une mauvaise dissolution des pigments dans la solution. Une pulv\u00e9risation irr\u00e9guli\u00e8re peut \u00e9galement en \u00eatre la cause.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>: Veillez \u00e0 ce que les pigments soient dispers\u00e9s uniform\u00e9ment dans la suspension de rev\u00eatement, souvent en utilisant des m\u00e9langeurs \u00e0 cisaillement \u00e9lev\u00e9 ou des \u00e9quipements de broyage.<\/p><h3><strong>4. Peau d&#039;orange \/ Rugosit\u00e9 de surface<\/strong><\/h3><p>Comme son nom l&#039;indique, la surface du comprim\u00e9 peut pr\u00e9senter un aspect granuleux ou textur\u00e9, semblable \u00e0 une peau d&#039;orange. Ce d\u00e9faut est d\u00fb \u00e0 un liquide d&#039;enrobage trop \u00e9pais, mal atomis\u00e9 ou \u00e0 s\u00e9chage rapide.<\/p><p>Par cons\u00e9quent, au lieu de former un film lisse, le rev\u00eatement s\u00e8che en couches irr\u00e9guli\u00e8res, ce qui donne un aspect rugueux aux comprim\u00e9s.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Diminuez la viscosit\u00e9 de la solution de rev\u00eatement en ajustant les proportions de solvants ou en utilisant une teneur en solides plus faible.<\/p><h3><strong>5. \u00c9rosion du noyau ou des bords<\/strong><\/h3><p>Lorsque les comprim\u00e9s pr\u00e9sentent des bords us\u00e9s ou un noyau expos\u00e9, c&#039;est un signe d&#039;\u00e9rosion. Les comprim\u00e9s qui absorbent trop de liquide d&#039;enrobage d\u00e9veloppent un noyau fragilis\u00e9. Cet exc\u00e8s d&#039;humidit\u00e9 rend le mat\u00e9riau interne mou et fragile.<\/p><p>Une vitesse de rotation \u00e9lev\u00e9e ou une manipulation brutale peuvent aggraver le probl\u00e8me, en frottant physiquement les bords pendant la rotation.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Ajustez avec pr\u00e9cision le d\u00e9bit de pulv\u00e9risation et les conditions de s\u00e9chage pour \u00e9viter le ramollissement, et maintenez une rotation mod\u00e9r\u00e9e du bac pour r\u00e9duire la friction.<\/p><h3><strong>6. \u00c9caillage<\/strong><\/h3><p>Ici, de petits fragments du rev\u00eatement se d\u00e9tachent des bords de la tablette, lui donnant un aspect ab\u00eem\u00e9 et cass\u00e9. Ce ph\u00e9nom\u00e8ne est souvent d\u00fb \u00e0 une vitesse de rotation \u00e9lev\u00e9e, \u00e0 une manipulation brutale ou \u00e0 des noyaux fragiles qui ne supportent pas les contraintes. Des bords fragiles sur le noyau favorisent ce probl\u00e8me.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>R\u00e9duisez l\u00e9g\u00e8rement la vitesse de la po\u00eale et v\u00e9rifiez la duret\u00e9 du noyau avant d&#039;enrober.<\/p><h3><strong>7. Pelage <\/strong><\/h3><p>Le d\u00e9collement est plus important lorsque des sections enti\u00e8res du rev\u00eatement se d\u00e9tachent de la surface de la tablette. Celle-ci semble alors se desquamer. Ce d\u00e9faut est d\u00fb \u00e0 une mauvaise adh\u00e9rence du rev\u00eatement au noyau, probablement caus\u00e9e par la pr\u00e9sence de poussi\u00e8re sur la tablette.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Ajuster la formulation pour am\u00e9liorer l&#039;adh\u00e9rence de l&#039;enrobage \u00e0 la surface du comprim\u00e9.<\/p><h3><strong>8. Ampoules<\/strong><\/h3><p>L&#039;air ou l&#039;humidit\u00e9 emprisonn\u00e9s sous la couche d&#039;enrobage peuvent se dilater. Cette dilatation cr\u00e9e des bulles \u00e0 la surface du comprim\u00e9 pendant le s\u00e9chage. Ces bulles peuvent ensuite \u00e9clater et laisser des asp\u00e9rit\u00e9s.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Abaisser la temp\u00e9rature de s\u00e9chage et permettre une \u00e9vaporation progressive du solvant, en laissant les gaz s&#039;\u00e9chapper en douceur.<\/p><h3><strong>9. Pontage du logo<\/strong><\/h3><p>Le masquage de logos peut masquer ou d\u00e9former les inscriptions, logos ou lettres sur la surface de la tablette. Au lieu d&#039;\u00eatre nets et pr\u00e9cis, les marquages apparaissent remplis ou flous.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Augmenter la pression d&#039;atomisation pour obtenir des gouttelettes plus fines, afin que le rev\u00eatement contourne les d\u00e9tails sans les recouvrir.<\/p><h2><strong>Diff\u00e9rents probl\u00e8mes de compression de tablettes<\/strong><\/h2><p>Avant l&#039;enrobage, les comprim\u00e9s subissent une compression, \u00e9tape tout aussi importante. C&#039;est \u00e0 ce stade que les poudres ou les granul\u00e9s sont press\u00e9s en comprim\u00e9s solides \u00e0 l&#039;aide de poin\u00e7ons et de matrices. Examinons les probl\u00e8mes qui surviennent \u00e0 cette \u00e9tape.<\/p><h3><strong>1. Coiffage et lamination<\/strong><\/h3><figure id=\"attachment_8823\" aria-describedby=\"caption-attachment-8823\" style=\"width: 425px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"size-full wp-image-8823\" src=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/11\/Tablet-capping-defect.png\" alt=\"D\u00e9faut de capsulage des comprim\u00e9s\" width=\"425\" height=\"244\" srcset=\"https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/11\/Tablet-capping-defect.png 425w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/11\/Tablet-capping-defect-300x172.png 300w, https:\/\/pharmamachinecn.com\/wp-content\/uploads\/2025\/11\/Tablet-capping-defect-18x10.png 18w\" sizes=\"(max-width: 425px) 100vw, 425px\" \/><figcaption id=\"caption-attachment-8823\" class=\"wp-caption-text\"><strong>D\u00e9faut de capsulage de la tablette.<\/strong> <strong style=\"font-size: 16px;\"><em>Source<\/em><\/strong><em style=\"font-size: 16px;\">: <\/em><a style=\"font-size: 16px; background-color: #ffffff;\" href=\"https:\/\/www.scientistlive.com\/content\/preventing-tablet-capping\" target=\"_blank\" rel=\"noopener\"><em><u>Scientifique en direct<\/u><\/em><\/a><\/figcaption><\/figure><p>Lorsqu&#039;une pellicule se d\u00e9tache du dessus d&#039;un comprim\u00e9, on parle de coiffage. En revanche, si les comprim\u00e9s sont divis\u00e9s en couches, les fabricants parlent de lamination. Ces deux d\u00e9fauts fragilisent le comprim\u00e9 et sont g\u00e9n\u00e9ralement caus\u00e9s par de l&#039;air emprisonn\u00e9 dans la poudre lors de la compression.<\/p><p>Une faible capacit\u00e9 de liaison dans la formulation peut rendre les comprim\u00e9s fragiles et susceptibles d&#039;\u00eatre endommag\u00e9s lors de l&#039;enrobage. Le probl\u00e8me s&#039;aggrave si\u2026 <a href=\"https:\/\/pharmamachinecn.com\/fr\/what-is-a-tablet-coating-machine\/\"><u>machine \u00e0 enrober<\/u><\/a>\u00a0fonctionne \u00e0 grande vitesse, \u00e0 mesure que la contrainte m\u00e9canique augmente.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Am\u00e9liorer l&#039;\u00e9coulement des granul\u00e9s en optimisant la granulation et en appliquant une force de compression l\u00e9g\u00e8rement sup\u00e9rieure.<\/p><h3><strong>2. Variation de poids<\/strong><\/h3><p>Il arrive que le poids des comprim\u00e9s d&#039;un m\u00eame lot diff\u00e8re sensiblement. Ces variations de poids indiquent une irr\u00e9gularit\u00e9 de production, ce qui affecte directement la pr\u00e9cision du dosage et la qualit\u00e9 du produit.<\/p><p>La principale cause est la faible fluidit\u00e9 des granul\u00e9s, qui emp\u00eache un remplissage uniforme de la cavit\u00e9 de la matrice. Parfois, un mauvais r\u00e9glage du doseur ou des pi\u00e8ces de la machine us\u00e9es peuvent \u00e9galement provoquer un remplissage irr\u00e9gulier.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Utilisez des agents fluidifiants comme la silice collo\u00efdale et \u00e9talonnez r\u00e9guli\u00e8rement les param\u00e8tres du doseur.<\/p><h2><strong>Probl\u00e8mes de traitement avant rev\u00eatement<\/strong><\/h2><p>Voici les difficult\u00e9s de traitement courantes qui surviennent avant le rev\u00eatement et leur impact sur le produit final.<\/p><h3><strong>1. S\u00e9chage inad\u00e9quat<\/strong><\/h3><p>L&#039;une des \u00e9tapes les plus souvent n\u00e9glig\u00e9es est le s\u00e9chage correct des comprim\u00e9s. Si ces derniers contiennent trop d&#039;humidit\u00e9, le processus d&#039;enrobage devient instable. Cette humidit\u00e9 excessive provoque alors des cloques, un collage ou des fissures une fois l&#039;enrobage appliqu\u00e9.<\/p><p>En revanche, si les comprim\u00e9s sont trop secs, ils peuvent devenir cassants, augmentant ainsi les risques d&#039;\u00e9caillage ou de rupture lors de l&#039;enrobage.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Appliquer des conditions de s\u00e9chage contr\u00f4l\u00e9es et surveiller constamment le taux d&#039;humidit\u00e9.<\/p><h3><strong>2. Propri\u00e9t\u00e9s de base des comprim\u00e9s de mauvaise qualit\u00e9<\/strong><\/h3><p>Le processus d&#039;enrobage d\u00e9pend fortement de la qualit\u00e9 du noyau du comprim\u00e9. Si les noyaux sont de forme irr\u00e9guli\u00e8re, tr\u00e8s poreux ou pr\u00e9sentent des surfaces rugueuses, l&#039;enrobage ne se r\u00e9partira pas uniform\u00e9ment.<\/p><p>Les comprim\u00e9s poreux absorbent la solution d&#039;enrobage de fa\u00e7on irr\u00e9guli\u00e8re. C&#039;est pourquoi des taches ou des zones plus fines se forment \u00e0 leur surface. Les comprim\u00e9s \u00e0 surface rugueuse pr\u00e9sentent un probl\u00e8me similaire, car l&#039;enrobage peine \u00e0 s&#039;\u00e9taler uniform\u00e9ment.<\/p><p><strong><em>Rem\u00e8de<\/em><\/strong>Optimiser la densit\u00e9 des granules pour r\u00e9duire la porosit\u00e9 et concevoir des comprim\u00e9s \u00e0 g\u00e9om\u00e9trie uniforme.<\/p><h2><strong>FAQ<\/strong><\/h2><h3><strong>1. Pourquoi mes comprim\u00e9s se cassent-ils sans cesse pendant l&#039;enrobage ?<\/strong><\/h3><p>Cela se produit g\u00e9n\u00e9ralement lorsque le noyau des comprim\u00e9s est trop fragile avant l&#039;enrobage. Ce ph\u00e9nom\u00e8ne est d\u00fb \u00e0 une faible concentration de liant, une granulation insuffisante ou un s\u00e9chage excessif. Lors du brassage dans la turbine d&#039;enrobage, les comprim\u00e9s s&#039;\u00e9br\u00e8chent ou se fissurent. La meilleure fa\u00e7on de pr\u00e9venir ce probl\u00e8me est d&#039;augmenter la concentration de liant, d&#039;optimiser le processus de s\u00e9chage et de v\u00e9rifier la duret\u00e9 avant l&#039;enrobage.<\/p><h3><strong>2. Que dois-je faire si les logos de ma tablette ne sont pas visibles apr\u00e8s le rev\u00eatement\u00a0?<\/strong><\/h3><p>Si les logos de votre tablette ne sont pas visibles, c&#039;est que la couche de rev\u00eatement a recouvert ou masqu\u00e9 le logo en relief. Si vous rencontrez le m\u00eame probl\u00e8me, r\u00e9duisez l&#039;\u00e9paisseur du rev\u00eatement, optimisez les param\u00e8tres de pulv\u00e9risation et utilisez des solutions de rev\u00eatement compatibles avec la gravure.<\/p><h2><strong>Signalez les d\u00e9fauts de votre tablette avant qu&#039;ils ne vous co\u00fbtent cher.<\/strong><\/h2><p>Pour les fabricants, il est imp\u00e9ratif de conna\u00eetre les d\u00e9fauts d&#039;enrobage des comprim\u00e9s et les solutions pour assurer la continuit\u00e9 de la production. N&#039;oubliez pas que ces d\u00e9fauts n&#039;affectent pas seulement la qualit\u00e9\u00a0; ils ont un impact direct sur votre chiffre d&#039;affaires et votre r\u00e9putation.<\/p><p>Mais la bonne nouvelle, c&#039;est que Finetech peut vous aider \u00e0 \u00e9liminer ces d\u00e9fauts de rev\u00eatement.<\/p><p>Notre technologie avanc\u00e9e <a href=\"https:\/\/pharmamachinecn.com\/fr\/pharmaceutical-manufacturing-process-equipment\/\"><u>fabrication pharmaceutique<\/u><\/a>\u00a0et les machines d&#039;emballage sont con\u00e7ues pour minimiser les erreurs et assurer le bon fonctionnement de votre ligne de production.<\/p><p><a href=\"https:\/\/pharmamachinecn.com\/fr\/request-a-quote\/\"><strong><em><u>Entrer en contact<\/u><\/em><\/strong><\/a><em>\u00a0D\u00e9couvrez comment Finetech peut p\u00e9renniser votre processus de fabrication !<\/em><\/p><h2><b>Avis de droit d'auteur :\u00a0<\/b><\/h2><p>Vous ne pouvez pas reproduire, modifier, publier, afficher, transmettre ou exploiter de quelque mani\u00e8re que ce soit le contenu de ce site web, ni utiliser ce contenu pour constituer une base de donn\u00e9es de quelque nature que ce soit, sans l'autorisation \u00e9crite expresse et pr\u00e9alable de Finetech Group. Pour obtenir l'autorisation d'utiliser le contenu, veuillez contacter : <a href=\"mailto:info@pharmamachinecn.com\"><span style=\"text-decoration: underline;\">info@pharmamachinecn.com<\/span><\/a><\/p><h2><b>Clause de non-responsabilit\u00e9:<\/b><\/h2><p>Les informations contenues dans cet article sont fournies \u00e0 titre d'information g\u00e9n\u00e9rale uniquement. L'entreprise ne garantit pas l'exactitude, la pertinence, l'actualit\u00e9 ou l'exhaustivit\u00e9 des informations, et l'entreprise n'assume aucune responsabilit\u00e9 en cas d'erreur ou d'omission dans le contenu de cet article.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Tablet coating may look simple on the surface, but anyone in pharma manufacturing knows it\u2019s where things usually go wrong. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8944,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[85],"tags":[],"class_list":["post-8819","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tablet-coating-equipment"],"acf":[],"_links":{"self":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts\/8819","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/comments?post=8819"}],"version-history":[{"count":14,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts\/8819\/revisions"}],"predecessor-version":[{"id":17087,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/posts\/8819\/revisions\/17087"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/media\/8944"}],"wp:attachment":[{"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/media?parent=8819"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/categories?post=8819"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmamachinecn.com\/fr\/wp-json\/wp\/v2\/tags?post=8819"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}